Digital First Dentistry › Dental radiography

Free verifiable CPD · 1 hour

Dental radiography: IR(ME)R, justification and optimisation

About this CPD

Format
Free online self-study, about 1 hour: this page, the required reading below, a five-question check and a short feedback form.
CPD hours
1 hour of verifiable CPD
Aim
To refresh the legal and clinical framework for taking dental radiographs safely in UK general practice.
Objectives
  • Name the two main sets of UK regulations that govern dental radiography and what each covers.
  • Describe the IR(ME)R duty holder roles: employer, referrer, practitioner and operator.
  • Explain justification, optimisation and the need for a recorded clinical evaluation of every exposure.
  • Describe how digital receptors, collimation and quality assurance help keep doses as low as reasonably practicable.
GDC development outcomes
  • C: Maintenance and development of knowledge and skill within your field of practice.
Provider and quality assurance
Provided by Bhavin Associates Ltd (company 07713563). Quality assured by Dr Bhavin Bhatt BDS MFGDP RCS (Eng), GDC 76358, for Bhavin Associates Ltd. See how CPD is quality assured.

Two sets of regulations

In Great Britain, dental X-ray use is governed by the Ionising Radiations Regulations 2017 (IRR17), which protect staff and the public, and the Ionising Radiation (Medical Exposure) Regulations 2017 (IR(ME)R), which protect patients. Northern Ireland has equivalent regulations. The GDC lists radiography and radiation protection as a highly recommended CPD topic, at 5 hours per cycle.

Duty holders under IR(ME)R

Employer: puts written procedures, protocols and quality assurance in place. Referrer: provides enough clinical information for the exposure to be justified. Practitioner: takes responsibility for justifying the exposure. Operator: carries out any practical aspect, such as positioning or pressing the button. In general practice one dentist often holds several roles, but each must be entitled in writing by the employer and adequately trained.

Justification

Every exposure must be justified for that patient: the expected diagnostic benefit must outweigh the risk, and the answer must not be available another way with less or no radiation. Routine radiographs taken "because it has been two years" without a clinical reason are not justified. Use recognised selection criteria, such as the FGDP(UK) guidance on selection criteria for dental radiography, which links intervals to caries and periodontal risk.

Optimisation

Doses must be kept as low as reasonably practicable while still answering the clinical question. Practical steps include rectangular collimation for intraoral films, beam-aiming devices, correct exposure settings for the receptor and patient size, and avoiding retakes through good technique.

Clinical evaluation

Every exposure needs a recorded clinical evaluation — what the image shows and what it means for the patient. An image that is taken but not reported is a failure of the process, not just of the record.

Digital imaging and the bigger picture

Digital receptors can reduce exposure and allow immediate review, but they do not remove the need for justification. Non-ionising tools — intraoral scans, photographs and near-infrared imaging where available — can support monitoring between radiographs, but they are adjuncts, not replacements, and none of them justifies skipping a radiograph that is clinically needed. For CBCT, see the separate module on CBCT justification.

Quality assurance

Practices need a radiation protection file, local rules, a named radiation protection supervisor, access to a radiation protection adviser and a medical physics expert, equipment testing, and regular image quality audits. Audit grades show whether retakes and poor images are being kept to a minimum.

Required reading

Read these short pages as part of this CPD:

Doing this as a team? Send it to your nurses and hygienists: WhatsApp · Email

Check your learning

Answer all five questions. You need four correct to continue. You can try again.

1. Which regulations primarily protect patients during dental X-ray exposures?

2. Who is responsible for justifying an individual exposure under IR(ME)R?

3. Which statement about justification is correct?

4. What must follow every radiographic exposure?

5. Which is a recognised optimisation measure for intraoral radiographs?

← All free CPD modules

Get the white paper and the starter guide

Free. Enter your email and both open straight away.

Tell us more (optional)

We use your email to send these resources, and updates only if you tick the box. Never shared. Unsubscribe any time.

Written by Dr Bhavin Bhatt BDS MFGDP RCS (Eng), GDC 76358 · Reviewed by Dr Bhatt 16 November 2026 · Editorial policy · Independence · Report an error