Digital First Dentistry › Radiography and radiation protection

Free verifiable CPD · 1 hour

Radiography and radiation protection: justifying CBCT in general practice

About this CPD

Format
Free online self-study, about 1 hour: this page, the required reading below, a five-question check and a short feedback form.
CPD hours
1 hour of verifiable CPD
Aim
To help dental professionals decide when cone beam CT is justified in general practice, and to use it in line with radiation protection principles.
Objectives
  • Explain why CBCT must be justified for each patient and why it is not a routine screening tool.
  • Describe how field of view and exposure settings affect dose.
  • Identify common justified uses in general practice.
  • Explain the need for a clinical evaluation of the whole volume, and when to seek a specialist report.
GDC development outcomes
  • C: Maintenance and development of knowledge and skill within your field of practice.
  • D: Maintenance of skills, behaviours and attitudes which maintain patient confidence in you and the dental professions and put patients’ interests first.
Provider and quality assurance
Provided by Bhavin Associates Ltd (company 07713563). Quality assured by Dr Bhavin Bhatt BDS MFGDP RCS (Eng), GDC 76358, for Bhavin Associates Ltd. See how CPD is quality assured.

Why justification comes first

Every radiographic exposure must be justified: it should follow a history and clinical examination, answer a question that matters, and be expected to change how the patient is managed. Cone beam CT (CBCT) is a useful adjunct to conventional radiography, but it generally gives a higher dose, so the case for each scan has to be clear. CBCT is not a routine screening tool and is not used for routine caries diagnosis.

What affects dose

  • Field of view: a small volume covering a few teeth usually means less dose and finer detail than a large volume covering the face.
  • Exposure factors, rotation and voxel size: choose the lowest settings that answer the clinical question.
  • Optimisation: keep exposures as low as reasonably practicable. A smaller dose does not make an unjustified scan acceptable.

Justified uses in general practice

  • Implant planning, where bone volume, the nerve or the sinus cannot be assessed adequately with conventional images.
  • Complex endodontics, such as suspected extra canals, resorption or failed treatment, when 2D images are inconclusive.
  • Impacted teeth close to important structures, after review of conventional radiographs.

Reporting the whole volume

Every exposure needs a clinical evaluation, and for CBCT that means the whole volume, not only the area of interest. Larger fields of view include structures outside most general dentists' training, so a specialist radiology report is often sought.

Refer or buy

Buying a CBCT unit brings duties beyond conventional radiography: room design, a radiation protection adviser, local rules, quality assurance, additional training and, in the UK, notification and registration with the regulator. Many practices refer until justified demand is steady. Logging every case for six months where CBCT would have been justified gives an honest picture.

UK guidance

In the UK, CBCT falls under the Ionising Radiations Regulations 2017 and the Ionising Radiation (Medical Exposure) Regulations 2017. The College of General Dentistry's Selection Criteria for Dental Radiography includes CBCT, and the Care Quality Commission expects practices in England to follow it. Specific guidance on the safe use of dental CBCT equipment is also published.

Required reading

Read these short pages as part of this CPD:

Doing this as a team? Send it to your nurses and hygienists: WhatsApp · Email

Check your learning

Answer all five questions. You need four correct to continue. You can try again.

1. Which statement about CBCT is correct?

2. What usually lowers dose and improves detail?

3. Which area of the volume needs a clinical evaluation?

4. Which is a commonly justified use in general practice?

5. Does a lower dose justify a scan that is not clinically indicated?

← All free CPD modules

Get the white paper and the starter guide

Free. Enter your email and both open straight away.

Tell us more (optional)

We use your email to send these resources, and updates only if you tick the box. Never shared. Unsubscribe any time.

Written by Dr Bhavin Bhatt BDS MFGDP RCS (Eng), GDC 76358 · Reviewed by Dr Bhatt 16 November 2026 · Editorial policy · Independence · Report an error